| 产品描述: |
| 在线报警器
主机价(含1个传感器)+ 电源+公共报警模块
传感器:8100/个(特殊有毒气体传感器除外)
机箱另购。
固定式气体检测报警系统,用于氧气,有毒气体及可燃气体
导轨式现代控制器,大大节省了空间,费用和安装时间。
传感器探头加上一台控制器即可组成一套完整的气体检测系统,测量数据可永久保存。
安装简单,使用方便
控制器电源和普通报警模块连在导轨控制器上。
传感器更换简单可行。
The system consists of an intrinsically safe sensor head communicating with a control module. Up to 9 control modules can be located in a 19”-rack where each combination sensor head - control module works as an independent detection system. Therefore the total system can be expanded without limitation.
System Reliability by Automatic Self Check
Today’s monitoring requirements demand a high degree of reliability and fault-free performance. The Statox system incorporates an automatic self check routine every 24 hours. The system completely verifies and tests all components including the sensor for proper operation. The sensor is dynamically tested via an internally generated target gas which assures that its’ response and recovery meet acceptable performance specifications. If a fault is detected in any of the components, it immediately notifies the control unit. The test can be initiated manually either from the control panel or the remote sensor head.
No electromagnetic interference
The remote sensor heads are made of chromium plated ABS. This makes them extremely sturdy and resistant to electromagnetic radiation. The Statox is CE – approved. Its safety against electromagnetic interference has been proven by a qualified laboratory.
One – man calibration and fault diagnosis
Sensor calibration and system fault diagnosis are easily achieved via the use of the Statox portable calibration and diagnostic unit. This intrinsically safe unit is connected by an optic coupler to the sensor head and allows one person to electronically calibrate a new sensor, diagnose any faults, or initiate a complete system test. All this is done without ever having to open the sensor head.
Central unit
½ l9"-rack maximum of 4
plug-in control panels: Dimensions: 180 x 270 x 420mm (h X w X d)
19"-rack maximum of 9
plug-in control panels:Dimensions: 180 x 485 x 420 mm (h X w X d)
Certificate: [E Ex ib] IIC
Plug-in control panel
Recorder output : 0 - 1 V, 4 - 20 mA
Alarms :dual-level, user adjustable
Relays : alarm 1, alarm 2, system fault, max. 24 V/100 mA
LED :alarm 1, alarm 2, system run, system fault
Data display: LED bar graph
Ambient temperature: 0 - 50 °C
Power supply : 230/115 V AC, 50/60 Hz
Power consumption :15 W per plug-in control panel
Certificate :E Ex ib IIC T6
Max. distance to sensor head:approx. 1200 m
|
|
|
|
| |
| |
M112718在线报警器的详细介绍
在线报警器
主机价(含1个传感器)+ 电源+公共报警模块
传感器:8100/个(特殊有毒气体传感器除外)
机箱另购。
固定式气体检测报警系统,用于氧气,有毒气体及可燃气体
导轨式现代控制器,大大节省了空间,费用和安装时间。
传感器探头加上一台控制器即可组成一套完整的气体检测系统,测量数据可永久保存。
安装简单,使用方便
控制器电源和普通报警模块连在导轨控制器上。
传感器更换简单可行。
The system consists of an intrinsically safe sensor head communicating with a control module. Up to 9 control modules can be located in a 19”-rack where each combination sensor head - control module works as an independent detection system. Therefore the total system can be expanded without limitation.
System Reliability by Automatic Self Check
Today’s monitoring requirements demand a high degree of reliability and fault-free performance. The Statox system incorporates an automatic self check routine every 24 hours. The system completely verifies and tests all components including the sensor for proper operation. The sensor is dynamically tested via an internally generated target gas which assures that its’ response and recovery meet acceptable performance specifications. If a fault is detected in any of the components, it immediately notifies the control unit. The test can be initiated manually either from the control panel or the remote sensor head.
No electromagnetic interference
The remote sensor heads are made of chromium plated ABS. This makes them extremely sturdy and resistant to electromagnetic radiation. The Statox is CE – approved. Its safety against electromagnetic interference has been proven by a qualified laboratory.
One – man calibration and fault diagnosis
Sensor calibration and system fault diagnosis are easily achieved via the use of the Statox portable calibration and diagnostic unit. This intrinsically safe unit is connected by an optic coupler to the sensor head and allows one person to electronically calibrate a new sensor, diagnose any faults, or initiate a complete system test. All this is done without ever having to open the sensor head.
Central unit
½ l9"-rack maximum of 4
plug-in control panels: Dimensions: 180 x 270 x 420mm (h X w X d)
19"-rack maximum of 9
plug-in control panels:Dimensions: 180 x 485 x 420 mm (h X w X d)
Certificate: [E Ex ib] IIC
Plug-in control panel
Recorder output : 0 - 1 V, 4 - 20 mA
Alarms :dual-level, user adjustable
Relays : alarm 1, alarm&
|
|
|