| The 902 advanced lead acetate based analyzer comes standard with the following equipment and features:
~ 24 VDC operation, for 110/220 VAC see options below
~ Dual isolated 4-20 ma outputs
~ 1-300 foot lead acetate tape included (The 902 can handle up to 350 feet of tape and will provide 30-60 days of measurement between tape changes)
~ Software includes all advanced configurable features for stream switching, automatic calibration, dual mode H2S and total sulfur measurement, reference gas test, and dual ranging
~ Modem compatible
~ Automatic self sensor balance on each cycle
~ Permeable membrane humidifier system
~ Fault detection for tape advance
~ "Windows" based software for configuration and monitoring
~ RS232/485 Modbus Protocol (requires optional card)
~ 6 SPDT alarm relays 5 amps @ 30 VDC or 8amps @ 120/240 VAC
~ 1- 2 amp 35 VDC solenoid driver (up to 4 more optional)
~ 8 character lighted display
~ 4 Dry contact digital inputs, 1 remote calibration (12/24 vdc)
~ Sample flowmeter and critical orifice restrictor installed
~ Handheld keypad user interface (I.S. on x-proof models)
~ 1 operation and maintenance manual
~ Sample vent eductor (prevents atmospheric pressure effects)
~ Low tape alarm
~ CSA approval (Certified for Hazardous and Div. 2 areas)
|
|
|
|
| |
| |
GAS1-902D2(MG) 硫化氢分析仪 的详细介绍
The 902 advanced lead acetate based analyzer comes standard with the following equipment and features:
~ 24 VDC operation, for 110/220 VAC see options below
~ Dual isolated 4-20 ma outputs
~ 1-300 foot lead acetate tape included (The 902 can handle up to 350 feet of tape and will provide 30-60 days of measurement between tape changes)
~ Software includes all advanced configurable features for stream switching, automatic calibration, dual mode H2S and total sulfur measurement, reference gas test, and dual ranging
~ Modem compatible
~ Automatic self sensor balance on each cycle
~ Permeable membrane humidifier system
~ Fault detection for tape advance
~ "Windows" based software for configuration and monitoring
~ RS232/485 Modbus Protocol (requires optional card)
~ 6 SPDT alarm relays 5 amps @ 30 VDC or 8amps @ 120/240 VAC
~ 1- 2 amp 35 VDC solenoid driver (up to 4 more optional)
~ 8 character lighted display
~ 4 Dry contact digital inputs, 1 remote calibration (12/24 vdc)
~ Sample flowmeter and critical orifice restrictor installed
~ Handheld keypad user interface (I.S. on x-proof models)
~ 1 operation and maintenance manual
~ Sample vent eductor (prevents atmospheric pressure effects)
~ Low tape alarm
~ CSA approval (Certified for Hazardous and Div. 2 areas)
|
|
|
|