联系我们
|
地 址:广州市先烈中路100号23-1栋219室 |
邮 编:510000 |
联系人:张体 |
电 话:020-87683635 |
传 真:020-87682522 |
邮 箱:cherryradiometer@126.com,radiometer@126.com |
|
|
|
|
|
ION 570法国 ION 570 多功能可滴定离子计
|
|
公司名称:
雷迪美特中国有限公司
|
参考价格:
未标明
|
发布时间:
2005-06-29
|
产品描述: |
多功能离子计,自带分辨率18000的滴定仪 |
|
|
|
|
|
ION 570法国 ION 570 多功能可滴定离子计的详细介绍
Potentiometric methods
- pH electrode calibration: up to 5 points using IUPAC standards or 4-7-10 Series buffers with error recognition on buffer used.
- pH with temperature-compensated reading: probe, entered or fixed at 25°C.
- Direct pH/mV measurements with recording on stable reading.
- Reagent addition: up to 3 simultaneous or consecutive additions.
- Sequencing of up to 10 methods, including electrode calibrations.
- Coupling of 2 to 6 methods in one beaker, including direct ISE and EC measurements.
Conductivity method (EC)
- Direct conductivity measurements with recording on stable reading.
- Conductivity with temperature-corrected display: none, natural water (ISO 7888), linear.
- Conductivity cell cable resistance compensation.
- Conductivity cell calibration: manual cell constant entry or automatic determination using 1, 0.1, 0.01 Demal KCl standards, NaCl 0.05% and standard sea water.
Ion-Selective Method (ISE)
- ISE measurements using standard additions or direct measurements with recording on stable reading.
- Additions or calibration with up to 9 points.
- Curves fitted using non-linear regression with CÆ detection limit determination according to IUPAC.
- Automatic standard additions: volumes programmed or automatically determined.
- Curve plotting: GRAN plot vs. Volume for standard additions, mV = f(pC) for ISE calibration.
Measuring Range
-9 to 23 pH
±2000 mV
4 µS to 400 mS
-10°C to +100°C
Resolution
0.001 pH
0.1 mV
Conductivity: 1/4000 of the scale
0.1°C
Printout
Automatic. GLP compliant.
Selectable: no, 80 columns, continuous, page to page. 3 levels of detail.
Laser or dot matrix printer.
Results
QC check on results with visual warning.
Statistical calculations.
Sample quantity recalculation before archiving.
Result recalculation.
Units
All standard units for samples/results.
Conductivity: µS/cm or mS/cm.
User-defined result units.
Storage capacity
Global password protection for programming access.
Non-volatile memory.
User programmable: 50 methods.
Libraries for 30 electrodes and 30 reagents: more than 30 electrodes and 20 reagents pre-identified with ID and type to help programming.
Storage of 200 results.
Stored parameters characterised by own ID, location and calibration data.
Embedded&nb
|
|
|
|